LINITHERM insulation systems
Attic insulation with LINITHERM P OSB

Abstand Menü

LINITHERM P OSB

Insulation of attic floors that can be walked on and loaded as drying lofts

Reliable insulation ...
  • Insulation that can be walked on and loaded
  • High compressive strength and dimensional stability
  • For storage space under the roof or for a drying loft
  • The high-quality Contifinish surface is water-repellent
  • Due to the minimum panel thickness, maximum room height is maintained

... in perfect professional quality ...
  • The serrations of the insulating core ensure fast installation without thermal bridges
  • Panels can be cut to size using standard woodworking tools
  • Homogeneous, full-surface insulation

... for PUR(E) energy saving
  • Protection from heat in summer
  • Thermal protection in winter
  • Insulating core made of PUR/PIR rigid foam
  • Consistently high insulation values (TCL 022)
  • High insulation values with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment

Attic insulation - LINITHERM P OSB
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: OSB panel, 8 mm thick
Edge joints: PUR/PIR rigid foam serrated on all sides, OSB panel with rabbet edges on all sides
Coverage: 1200 x 600 mm (for calculation) (coverage is 1 cm less)
Thickness mm
total
Thickness mm
PUR/PIR
Thickness mm
OSB panel
Package contents
Quantity / m²
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
68 60 8 4 2.88 64 46.1 022 0.34
78 70 8 4 2.88 56 40.3 022 0.30
88 80 8 3 2.16 48 34.6 022 0.26
108 100 8 3 2.16 42 30.2 022 0.21
128 120 8 3 2.16 36 25.9 022 0.18
148 140 8 2 1.44 32 23.0 022 0.15
168 160 8 2 1.44 28 20.2 022 0.13
188 180 8 2 1.44 24 17.3 022 0.12
Other thicknesses on request; delivery only whole packages.
1 U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.04 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.