Insulation for outside walls
Insulation for outside walls - LINITHERM PAL W

Abstand Menü

LINITHERM PAL W

Slim thermal protection for core insulation and rear-ventilated façade constructions

Reliable, full thermal protection...
  • The building is nicely wrapped up and warm
  • Highly effective protection from heat & cold, damage from humidity, and mould growth
  • The insulation raises the surface temperature of the interior wall
  • No circulation draughts, as is usual with cold wall surfaces

... in perfect professional quality ...
  • Easy handling thanks to manageable dimensions and a low weight
  • With integral vapour barrier
  • Full-surface, seamless insulation
  • Installation without thermal bridges
  • High compressive strength and dimensional stability
  • Flame retardant – fire behaviour class C-s2, d0 acc. to DIN EN 13501-1

... for new and old buildings ...
  • Not thicker,
  • but better insulation

... for PUR(E) energy saving
  • Protection from heat in summer
  • Thermal protection in winter
  • Insulating core made of PUR/PIR rigid foam
  • Consistently high insulation values (TCL 022)
  • Maximum insulation with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment

Insulation for outside walls - LINITHERM PAL W
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, fire behaviour class C-s2,d0 acc. to DIN EN 13501-1 (corresponds to national building inspection class "flame retardant") as specified in Permit Z-23.15-1436, aluminium foil on both sides
Edge joints: Blunt cut on all sides or with rabbet edges
Outside dimensions: 1200 x 600 mm (for calculation) (coverage is 2 cm less with rabbet edges)
Thickness mm
total
Package contents
Quantity / m²
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
80 6 4.32 60 43.2 022 0.26
100 5 3.60 50 36.0 022 0.21
120 4 2.88 40 28.8 022 0.18
140 3 2.16 30 21.6 022 0.15
160 3 2.16 30 21.6 022 0.13
Other thicknesses on request. Delivery only whole packages. Surcharge for rabbet edges


LINITHERM fire lock bar
Assembly bracket: V2A-profile thickness 1 mm; with 6 mm slotted holes for mounting
Reactive airing profile: Aluminum expanded metal with a reactive coating
Length mm Height mm Depth mm
150 110 80
Other versions on request
1 U-value, taking the thermal transfer resistance Rsi = 0.13 [m²K/W] and Rse = 0.04 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.