Insulation of cellar ceilings
Insulation of cellar ceilings with LINITHERM PAL KD

Abstand Menü

LINITHERM PAL KD | PAL KD white | PAL KD Top

Insulated cellar ceilings for warm feet in residential rooms

LINITHERM PAL KD - with aluminium foil on both sides for fast and simple insulation of cellar ceilings.
LINITHERM PAL KD white - with aluminium foil on both sides. Light is reflected by the white surface of the visible side. Cellar rooms are brighter and more friendly.
LINITHERM PAL KD Top - with aluminium foil on both sides, white-coated decorative chipboard facing on interior surface.
For cellars that are to be used as party, hobby or workroom.

Reliable insulation ...
  • For warm floors underfoot in living areas
  • A simple method of eliminating the cold bridge between heated and unheated rooms
  • Dimensionally stable and pressure resistant
  • Minimum reduction of room height

... in perfect professional quality ...
  • With special edge joints
  • With integral vapour barrier
  • Full-surface, seamless insulation

... for PUR(E) energy saving
  • Insulating core made of PUR/PIR rigid foam
  • Consistently high insulation values (TCL 022)
  • Optimum insulation with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment.

Insulation of cellar ceilings - LINITHERM PAL KD
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Edge joints: Blunt cut on all sides
Coverage: 1200 x 600 mm (for calculation)
Thickness mm
PUR/PIR
Package contents
Quantity / m²
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
40 12 8.64 120 86.4 022 0.50
60 8 5.76 80 57.6 022 0.35
80 6 4.32 60 43.2 022 0.26
100 5 3.60 50 36.0 022 0.21
120 4 2.88 40 28.8 022 0.19
Other thicknesses on request; delivery only whole packages.


Insulation of cellar ceilings - LINITHERM PAL KD white
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: Visible face = aluminium foil, coated white
Edge joints: Grooved on all sides for H-type joining profile
Coverage: 1200 x 600 mm (= for calculation)
Thickness mm
PUR/PIR
Package contents
Quantity / m²
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
40 12 8.64 120 86.4 022 0.50
60 8 5.76 80 57.6 022 0.35
80 6 4.32 60 43.2 022 0.26
100 5 3.60 50 36.0 022 0.21
Other thicknesses on request; delivery only whole packages.


Insulation of cellar ceilings - LINITHERM PAL KD Top
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: Visible side = laminated chipboard panel, 3 mm thick, white coating
Edge joints: Grooved on all sides for H-type joining profile
Coverage: 1500 x 1200 mm (= for calculation)
Thickness mm
total
Thickness mm
PUR/PIR
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
43 40 56 100.8 022 0.50
63 60 38 68.4 022 0.34
83 80 28 50.4 022 0.26
Other thicknesses on request.
1 U-value, taking the thermal transfer resistance Rsi = 0.0 [m²K/W] and Rse = 0.17 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.