LINITHERM insulation systems
Over-rafter insulation system - LINITHERM PAL OSB

Abstand Menü

LINITHERM PAL OSB

Attachments for metal roofing can be located anywhere on the derived wood panel bonded to the over-rafter insulating system

Reliable insulation ...
  • Insulation under metal roof
  • Protection from electrosmog

... in perfect professional quality ...
  • With integral vapour barrier
  • Derived wood panel bonded on in the factory
  • Time-saving and economical installation with full-surface supporting structure for the panelling
  • The roofing can be mechanically attached in any location
  • In combination with LINITHERM IngBau screws, static loads can be transferred reliably
  • High compressive strength
  • Full-surface, seamless insulation
  • Intended for existing and newly boarded roofs

... for PUR(E) energy saving
  • Protection from heat in summer
  • Thermal protection in winter
  • Insulating core made of PUR/PIR rigid foam
  • Consistently high insulation values (TCL 022)
  • Maximum insulation with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment

Over-rafter insulation system - LINITHERM PAL OSB
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: Covered with a 22 mm derived wood panel for attaching the metal roofing
Edge joints: Tongue & groove pressfit joints on all sides, derived wood panel with T&G
Please note: When building the sub-roof and the entire roof support structure, the rules of the trade as well as the notes and guidelines in the separate Linzmeier leaflet must be observed.
Coverage: 2420 x 580 mm (for calculation)
Thickness mm
total
Thickness mm
PUR/PIR
Thickness mm
Derived wood panel
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
102 80 22 21 29.5 022 0.24
122 100 22 17 23.9 022 0.20
142 120 22 15 21.1 022 0.17
162 140 22 13 18.2 022 0.15
182 160 22 11 15.4 022 0.13
1 U-value, taking the thermal transfer resistance Rsi and Rse and a 19 mm wood boarding into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.