LINITHERM insulation systems
Over-rafter insulation system - LINITHERM PAL SIL T

Abstand Menü

LINITHERM PAL SIL T

Combined over-rafter insulation system with silicate panel facing – can be plastered, wallpapered, and painted

Reliable insulation ...
  • The bonded silicate facing permits interior surfaces to be plastered, painted, or wallpapered – an ideal solution where rafters are to remain visible
  • Impact resistant, e.g. thrown balls
  • Protection from electrosmog

... in perfect professional quality ...
  • With integral vapour barrier
  • Airtight facing applied in the factory
  • With printed grid for fast installation
  • Full-surface, seamless insulation
  • For installation on the rafters

... for PUR(E) energy saving
  • Protection from heat in summer
  • Thermal protection in winter
  • Consistently high insulation values (TCL 022)
  • Maximum insulation with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment

Insulation values for the overall construction

U-value 1 [W/(m²K)]
Thickness
overall construction

(mm)
Thickness
PAL SIL T
(TCL 022)
(mm)
Thickness
of additional
insulation
(mm)
PAL N+F
PAL Polymer
PAL 2U
(TCL 022)
PAL 2UM
(TCL 022 + 039)
PAL HT
(TCL 022 + 039)
PGV T
(TCL 028)
(TCL 026)
(TCL 025)
116 66 50 - - 0.21
126 66 60 - - 0.20
146 66 80 0.15 - 0.17
166 66 100 0.13 - 0.15
186 66 120 0.12 0.13 0.13
206 66 140 0.11 0.12 0.12
226 66 160 0.10 0.11 0.11
246 66 180 0.09 0.10 0.10
266 66 200 0.08 0.09 0.09


Over-rafter insulation system - LINITHERM PAL SIL T
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides = vapour barrier
Facing: Upper side coated with tear-resistant, slip-resistant diffusion membrane, approx. 8 cm overlap lengthwise and transverse, complete with sealing tape. Inner side with 6 mm thick silicate facing (non-flammable, resistant to moisture, can be painted, or wallpapered).
Kantenverbindung: Tongue & groove pressfit joints on all sides, silicate facing bevelled all around
Coverage: 2480 x 1180 mm (for calculation)
Thickness mm
total
Thickness mm
PUR/PIR
Thickness mm
Silicate facing
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
66 60 6 36 105.35 022 0.34
1 U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.1 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.