LINITHERM insulation systems
Below-rafter insulation with LINITHERM PAL GK

Abstand Menü

LINITHERM PAL GK
LINITHERM PAL GKL

Insulation system installed below the rafters or collar beams for improving the existing between-rafter insulation

Reliable insulation ...
  • Minimum thickness for more living space
  • Interior surface can be plastered and wallpapered
  • Protection from electrosmog
  • Correct construction in terms of building physics

... in perfect professional quality ...
  • Installation below the rafters
  • No additional slat framework required
  • With integral vapour barrier
  • Full-surface, seamless insulation

... for PUR(E) energy saving
  • Protection from heat in summer
  • Thermal protection in winter
  • Insulating core made of PUR/PIR rigid foam
  • Consistently high insulation values (TCL 022)
  • Maximum insulation with minimum panel thickness
  • Positive building biology: PUR/PIR rigid foam is free of CFC, HCFC, formaldehyde, and fibres
  • Positive life-cycle assessment

Below-rafter insulation - LINITHERM PAL GK
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: Plasterboard facing on the inner side, 9.5 mm thick
Edge joints: Lengthwise butt edge grooved for key (included in delivery)
Transverse butt edge with T&G pressfit joint
Outside dimensions: 2500 x 600 mm (= for calculation)
Thickness mm
total
Thickness mm
PUR/PIR
Thickness mm
Plasterboard
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
39.5 30 9.5 45 67.5 022 0.65
49.5 40 9.5 36 54.0 022 0.50
69.5 60 9.5 26 39.0 022 0.34
89.5 80 9.5 20 30.0 022 0.26
109.5 100 9.5 17 25.5 022 0.21
Other thicknesses on request.


LINITHERM PAL GKL

Same as LINITHERM GK, but with additional integral battens to compensate for irregularities of the roof structure


Below-rafter insulation - LINITHERM PAL GKL
Insulation core: PUR/PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides
Facing: Plasterboard facing on the inner side, 9.5 mm thick
System: With integral battens for compensating irregularities in the roof structure during installation with adjusting screws (no additional slat framework required)
Edge joints: Tongue & groove pressfit joints on long sides, short sides with rabbet edge
Outside dimensions: 2500 x 600 mm (for calculation) (coverage is 2 cm less)
Thickness mm
total
Thickness mm
PUR/PIR
Thickness mm
Plasterboard
Pallet contents
Quantity / m²
TCL
PUR/PIR
U-value 1
[W/(m²K)]
49.5 40 9.5 36 55.8 022 0.55
69.5 60 9.5 26 40.3 022 0.37
Other thicknesses on request.
1 U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.04 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account.